Part Number Hot Search : 
GJ20T03 EL2120CS 00150 1100T CX258 ES51982 BA1335 20MHZ
Product Description
Full Text Search
 

To Download MB4012D12RW Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  key features: ? 40w output power ? 2:1 input voltage range ? 1,500 vdc isolation ? single & dual outputs ? ef? ciency to 91% ? compact 1 x 2 inch case ? wide temp operation ? industry standard pin-out ? low cost mb4000rw compact, 1 x 2 inch 40w, 2:1 input range dc/dc con vert ers electrical speci? cations speci cations typical @ +25?, nominal input voltage & rated output current, unless otherwise noted. speci cations subject to change without notice. www.micropowerdirect.com micropower direct 292 page street suite d stoughton, ma 02072 usa t: (781) 344-8226 f: (781) 344-8481 e: sales@micropowerdirect.com w: www.micropowerdirect.com series input parameter conditions min. typ. max. units input start voltage 12 vdc input 9.0 vdc 24 vdc input 18.0 48 vdc input 36.0 input shutdown voltage 12 vdc input 8.3 vdc 24 vdc input 16.5 48 vdc input 33.0 input filter lc filter start-up time see note 1 30 ms output parameter conditions min. typ. max. units output voltage accuracy ?.0 % output voltage balance dual output , balanced loads ?.0 % line regulation v in = min to max ?.5 % load regulation, min load to full load single output models ?.5 % dual output models ?.0 cross regulation see note 2 ?.0 % ripple & noise, see note 3 3.3 & 5.0 vout models 100 mv p - p 12, 15 & 24 vout models 150 mv p - p dual output models 150 mv p - p transient recovery time, see note 4 25% load step change 250 ?ec transient response deviation ?.0 ?.0 % temperature coef cient ?.02 %/? over temperature protection shutdown temperature 110 ? output power protection 150 % output short circuit, see note 5 continuous (autorecovery) general parameter conditions min. typ. max. units isolation voltage 60 seconds 1,500 vdc isolation resistance 500 vdc 1,000 m isolation capacitance 100 khz, 1v 1,500 pf switching frequency see note 6 320 khz environmental parameter conditions min. typ. max. units operating temperature range, ambient without heatsink mb40xxs-03rw -40 +25 +66 ? mb40xxs-05rw, -12rw, -15rw, -24rw +46 mb40xxd-xxrw +40 operating temperature range, ambient with heatsink mb40xxs-03rw -40 +25 +73 ? mb40xxs-05rw, -12rw, -15rw, -24rw +57 mb40xxd-xxrw +52 operating temperature range case +105 ? storage temperature range -50 +125 ? cooling free air convection humidity rh, non-condensing 95 % physical case size, see note on page 4 2.0 x 1.0 x 0.40 inches (50.8 x 25.4 x 10.2 mm) case material metal with non-conductive base weight 1.06 oz (30g) reliability speci? cations parameter conditions min. typ. max. units mtbf mil hdbk 217f, 25?, gnd benign 328 khours absolute maximum ratings parameter conditions min. typ. max. units input voltage surge (1 sec) 12 vdc input -0.7 25.0 vdc 24 vdc input -0.7 50.0 48 vdc input -0.7 100.0 lead temperature 1.5 mm from case for 10 sec 260.0 ? caution: exceeding absolute maximum ratings may damage the module. these are not continuous operating ratings.
model selection guide 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com notes: 1. start up time is measured at nominal input and with a constant resistive load. 2. cross regulation is measured with the output being tested at 100% load. the second output is varied from 25% to 100% load. 3. when measuring output ripple, it is recommended that an external 1 ? capacitor and 10 ? capacitor be connected in parallel from the +v out to the -v out pins for single output units and from each output to common for dual output units. 4. transient recovery is measured to within a 1% error band for a load step change of 25%. 5. short circuit protection is provided by a ?iccup mode circuit. 6. the switching frequency for 24 vdc output models is 285 khz. 7. operation at no-load will not damage these units. however, they may not meet all speci cations if operated below the speci ed minimum load. 8. it is recommended that a fuse be used on the input of a power supply for protection. see the model selection table above for the correct rating. on single output units, an external resister may be added to adjust the converter output. to adjust the output up, connect a 5%, 3w resistor between the minus output pin (5) and the vout trim pin (6). to adjust the output down, connect a 5%, 3w resistor between the plus output pin (4) and the vout trim pin (6). the trim table at right gives suggested resistor values for this adjustment. external trim for heatsink option, add suf x ??to model number (i.e. mb4012s-05rw-h ) model number input output ef? ciency (%, typ) over voltage protection (vdc) capacitive load (f max) fuse rating slow-blow (a) voltage (vdc) current (ma) voltage (vdc) current (ma, max) current (ma, min) nominal range full-load no-load mb4012s-03rw 12 9.0 - 18.0 2,470 120 3.3 8,000 0 89 3.9 21,000 8.0 mb4012s-05rw 12 9.0 - 18.0 3,750 160 5.0 8,000 0 89 6.2 13,600 8.0 mb4012s-12rw 12 9.0 - 18.0 3,750 160 12.0 3,330 0 89 15.0 2,400 8.0 mb4012s-15rw 12 9.0 - 18.0 3,700 150 15.0 2,670 0 90 18.0 1,500 8.0 mb4012s-24rw 12 9.0 - 18.0 3,670 160 24.0 1,670 0 91 30.0 600 8.0 mb4012d-12rw 12 9.0 - 18.0 3,790 70 ?2.0 ?,670 ?45 88 ?5.0 ?,200 8.0 mb4012d-15rw 12 9.0 - 18.0 3,790 60 ?5.0 ?,330 ?10 88 ?8.0 ?50 8.0 mb4024s-03rw 24 18.0 - 36.0 1,220 75 3.3 8,000 0 90 3.9 21,000 4.0 mb4024s-05rw 24 18.0 - 36.0 1,830 80 5.0 8,000 0 91 6.2 13,600 4.0 mb4024s-12rw 24 18.0 - 36.0 1,830 85 12.0 3,330 0 91 15.0 2,400 4.0 mb4024s-15rw 24 18.0 - 36.0 1,830 75 15.0 2,670 0 91 18.0 1,500 4.0 mb4024s-24rw 24 18.0 - 36.0 1,835 85 24.0 1,670 0 91 30.0 600 4.0 mb4024d-12rw 24 18.0 - 36.0 1,870 50 ?2.0 ?,670 ?45 89 ?5.0 ?,200 4.0 mb4024d-15rw 24 18.0 - 36.0 1,870 45 ?5.0 ?,330 ?10 89 ?8.0 ?50 4.0 mb4048s-03rw 48 36.0 - 75.0 610 40 3.3 8,000 0 90 3.9 21,000 2.0 mb4048s-05rw 48 36.0 - 75.0 920 50 5.0 8,000 0 91 6.2 13,600 2.0 mb4048s-12rw 48 36.0 - 75.0 910 50 12.0 3,330 0 92 15.0 2,400 2.0 mb4048s-15rw 48 36.0 - 75.0 910 50 15.0 2,670 0 92 18.0 1,500 2.0 mb4048s-24rw 48 36.0 - 75.0 918 50 24.0 1,670 0 91 30.0 600 2.0 mb4048d-12rw 48 36.0 - 75.0 940 65 ?2.0 ?,670 ?45 89 ?5.0 ?,200 2.0 mb4048d-15rw 48 36.0 - 75.0 940 65 ?5.0 ?,330 ?10 89 ?8.0 ?50 2.0 mb40xxs-03rw trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 72.61 32.55 19.20 12.52 8.51 5.84 3.94 2.51 1.39 0.50 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 60.84 27.40 16.25 10.68 7.34 5.11 3.51 2.32 1.39 0.65 k  mb40xxs-05rw trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 138.88 62.41 36.92 24.18 16.53 11.44 7.79 5.06 2.94 1.24 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 106.87 47.76 28.06 18.21 12.30 8.36 5.55 3.44 1.79 0.48 k  mb40xxs-12rw trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 413.55 184.55 108.22 70.05 47.15 31.88 20.98 12.80 6.44 1.35 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 351.00 157.50 93.00 60.75 41.40 28.50 19.29 12.37 7.00 2.70 k  mb40xxs-15rw trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 530.73 238.61 141.24 92.56 63.35 43.87 29.96 19.53 11.41 4.92 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 422.77 189.89 112.26 73.44 50.15 34.63 23.54 15.22 8.75 3.58 k  mb40xxs-24rw trim down vout v o x 0.99 v o x 0.98 v o x 0.97 v o x 0.96 v o x 0.95 v o x 0.94 v o x 0.93 v o x 0.92 v o x 0.91 v o x 0.90 volts r down 333.39 148.80 87.26 56.50 38.04 25.73 16.94 10.35 5.22 1.12 k  trim up vout v o x 1.01 v o x 1.02 v o x 1.03 v o x 1.04 v o x 1.05 v o x 1.06 v o x 1.07 v o x 1.08 v o x 1.09 v o x 1.10 volts r up 243.70 108.50 63.43 40.90 27.38 18.37 11.93 7.10 3.34 0.34 k 
micropower direct 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com mb40xxs-03rw without heatsink mb40xxs-03rw with heatsink mb40xxs-05rw, -12rw, -15rw, -24rw without heatsink mb40xxs-05rw, -12rw, -15rw, -24rw with heatsink mb40xxd-12rw, mb40xxd-15rw without heatsink mb40xxd-12rw, mb40xxd-15rw with heatsink derating curves www.micropowerdirect.com external component connection emc speci? cations parameter standard radiated emissions en 55022 class a conducted emissions en 55022 class a esd en 61000-4-2 criteria b; ? kv air, ? kv contact rs en 61000-4-3 criteria a; 10v/m eft, see notes en 61000-4-4 criteria a; ? kv surge, see notes en 61000-4-5 criteria b; ? kv cs en 61000-4-6 criteria a; 10 v/m notes: all units should meet en 55022 (ce/re) class a/b with the simple external circuit shown at right. to meet the requirements of en 61000-4-4 and en 61000-4-5, the value of c 1 should be changed to 330 f/200v. contact the factory for more information. standard model c 1 c 2 l 1 c 3 c 4 c 5 c 6 en55022 class a mb4012x-xxrw 10 ?/25v 1812 mlcc --- --- --- --- 1,000 pf/2kv 1808 mlcc 1,000 pf/2kv 1808 mlcc mb4024x-xxrw 4.7 ?/50v 1812 mlcc --- --- --- --- 1,000 pf/2kv 1808 mlcc 1,000 pf/2kv 1808 mlcc mb4048x-xxrw 2.2 ?/100v 1812 mlcc --- --- --- --- 1,000 pf/2kv 1808 mlcc 1,000 pf/2kv 1808 mlcc en55022 class b mb40xxs-xxrw 3.3 ?/100v 1210/x7s 3.3 ?/100v 1210/x7s 1 mh 3.3 ?/100v 1210/x7s 3.3 ?/100v 1210/x7s 1,000 pf/2kv 1808 x7r 1,000 pf/2kv 1808 x7r mb40xxd-xxrw 3.3 ?/100v 1210/x7s 3.3 ?/100v 1210/x7s 1 mh 3.3 ?/100v 1210/x7s 3.3 ?/100v 1210/x7s 1,000 pf/2kv 1808 x7r 1,000 pf/2kv 1808 x7r parameter min typ max units supply on 3.5 12.0 vdc supply off 0.0 1.2 vdc standby input current 2.5 ma control common referenced to negative input (pin 2) control input current (on) 0.5 ma contr ol input current (off) -0.5 ma remote on/off applying a signal to pin 3 will turn the unit on/off. if the pin is left open, the unit operates. if grounded, the unit will shut off. the speci cations for the on/off function are given in the table at left.
micropower direct we power your success - for less! 292 page street ste d stoughton, ma 02072 tel: (781) 344-8226 fax: (781) 344-8481 e-mail: sales@micropowerdirect.com www.micropowerdirect.com notes: all dimensions are typical in inches (mm) tolerance x.xx = ?.02 (?.50) heatsink is black, anodized aluminum mechanical dimensions mechanical dimensions: with optional heatsink pin single output 1+vin 2-vin 3 remote on/off 4 +vout 5 -vout 6 trim pin dual output 1+vin 2-vin 3 remote on/off 4 +vout 5 common 6 -vout pin con nec tions for the heatsink option, add suf x ??to the model number (i.e. mb4048s-24rw-h)


▲Up To Search▲   

 
Price & Availability of MB4012D12RW

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X